Time for action – setting the threshold and creating an incident for estimated failover time metric
Perform the following steps to set a threshold and create an estimated failover time metric:
Open the database home page for the standby database by navigating to Targets | Databases and then clicking on the name of the standby database.
Navigate to the metrics page by navigating to Oracle Database | Monitoring | All Metrics.
Expand the Data Guard Performance category and click on the Estimated Failover Time section:
Click on Modify Thresholds. Enter
15
for Warning Threshold and20
for Critical Threshold. Then click on Save Thresholds:Navigate to the Data Guard Administration page by navigating to Availability | Data Guard Administration. Click on Edit to edit the standby database properties.
Stop the Redo Apply process by selecting Apply Off and click on Apply:
Navigate to the Data Guard performance page by navigating to Availability | Data Guard Performance and start the test application. After...