- False. In this chapter, the ST-Link on the Nucleo development board was re-flashed to provide the same functionality as a J-Link.
- False. There are many ways to verify the timing requirements of a real-time system. Segger SystemView provides a means to measure response time, as does looking at system inputs and outputs via a traditional logic analyzer.
- False. An RTOS-aware debugger provides the ability to view all of the stacks in the system. This is also an option with any Open GDB-based debugging using Eclipse, as mentioned in the previous chapter.
- False. Each module that you write should be tested as thoroughly as possible to minimize any surprises and complex interactions when it is time to integrate the modules and perform a system-level test.
- Unit testing. In unit testing, each individual module is tested as it is developed. Integration testing is testing to ensure...