Learning about the FC switching mode
Similar to LAN connectivity, UCS Fabric Interconnects support two types of switching modes: FC EHM and the FC switching mode. The default switching mode is an end-host mode where UCS appears as a number of hosts attached to the upstream switch. This is also known as N-Port Virtualization (NPV) and requires an NPIV-capable fabric switch for providing the fiber login services.
The other option available is the native FC switching mode where UCS Fabric Interconnect appears as a native FC fabric switch. Switching between FC modes is a disruptive process and hence should be arranged in a scheduled maintenance window.
In order to configure or verify the end-host mode for the Fabric Interconnects, perform the following steps:
- Log into UCS Manager.
- Click on the
Equipment
tab in the navigation pane. - In the
Equipment
tab, click onFabric Interconnect A
(as shown in the following screenshot). - The
Status
area in the work pane shows the currentFC Mode
configuration, which...