Configuring the FC port channel and trunking
Similar to an Ethernet port channel, a FC port channel or trunk can be created to aggregate multiple physical FC links into a single logical link to provide higher throughput and redundancy. A maximum of 16 uplink ports can be aggregated in a port channel.
Perform the following steps to configure the FC port channel:
- Log into UCS Manager.
- Click on the
SAN
tab in the navigation pane. - In the
SAN
tab, expandSAN
and thenSAN Cloud
. - Right-click on FC Port Channel and click on
Create Port Channel
as shown in the screenshot.
Â
- In the pop-up window, set the port channel ID and
Name
as shown in the screenshot:
- Click on
Next
. - On the next screen, drag the appropriate ports to the port channel and click on
Add Ports
. - Repeat the steps for both VSANs.